BT is not prolonged in coagulation disorders such as the hemophilias.
Limitations
These include the operator’s variability in technique, limited precision, accuracy, reproducibility, and also variability in the same patients at different times. “In vitro” BT equipment, such as platelet function analyzer (PFA 100), is better standardized and has better reproducibility.
Many health care organizations have discontinued the use of BT entirely
.
BLOOD GAS, pH
Definition
pH is the negative logarithm of the hydrogen ion concentration and is an index of acidity and alkalinity of the blood. It changes nonlinearly masking magnitude of acid–base disorders. The hydrogen ion concentration is dictated by the ratio of two quantities: the HCO
3
− concentration, which is regulated by the kidneys, and the PCO
2
, which is controlled by the lungs.
Normal range:
Arterial: 7.35–7.45
Venous: 7.31–7.41
Use
To evaluate acid–base disorders
Interpretation
Increased In
Metabolic alkalosis (plasma bicarbonate excess)